NMR Spectrometers

The research laboratory currently houses 15 Bruker FT NMR instruments (13 solution, 2 solids) with 1H operating frequencies between 200 and 700 MHz, offering a wide range of capabilities. These include cryogenic probes, multinuclear probes, variable temperature NMR, solid-state NMR, high-power diffusion NMR and micro-imaging. There is also a Bruker AVIIIHD 400 MHz system housed in the Chemistry Teaching Laboratory (CTL).

Summary of all open-access spectrometer queues is available here. Note that departmental login / VPN is required.

All the below information was correct as of August 2026.

 

Bruker DPX200

 

Image
dpx200

Spectrometer nickname: DPX200 (not to be used in publications)

Location: CRL 30.049 (first floor, open-access NMR lab)

Spectrometer, probe & software specifications: Bruker DPX 200 MHz spectrometer running TopSpin 1.3 with a DPX console, equipped with a 5 mm, 2-channel 13C/1H dual probe

Sample changer: Manual sample exchange

Access level: Open-access instrument operation

Experiments: 1D 1H NMR spectra only for routine analysis and quick screening (see the list of available experiments).

Spectrometer details for publication requirements: NMR spectra were recorded on a Bruker DPX 200MHz NMR spectrometer, equipped with a 5 mm, 2-channel 13C/1H dual probe using the software TopSpin (version 1.3, Bruker BioSpin)

Hg400: Bruker AVIIIHD 400 Nanobay

Image
hg400 web

Spectrometer nickname: Hg400 (not to be used in publications)

Location: CRL 40.051 (second floor open-access NMR lab)

Spectrometer, probe and software specifications: 2-channel Bruker AVIII HD nanobay 400 MHz spectrometer running TopSpin 3, equipped with a 5 mm z-gradient multinuclear BBFO probe

 

Sample changer: 60-position Bruker Sample Xpress robotic sample changer

Access level: Open-access instrument operation

Experiments: Routine 1H and 13C based 1D and 2D experiments as well as additional multinuclear experiments supporting inorganic chemistry

History lists: Click here or copy and paste this link into a browser (note departmental login / VPN is required): file://chem.ox.ac.uk/SRF/NMR/Hg400/setup.html

Spectrometer details for publication requirements: NMR spectra were recorded on a Bruker AVIII HD Nanobay 400 MHz NMR spectrometer, equipped with a 5 mm z-gradient multinuclear BBFO probe using the software TopSpin (version 3, Bruker BioSpin)

Venus400: Bruker AVIIIHD 400 Nanobay

Image
venus400 web

Spectrometer nickname: Venus400 (not to be used in publications)

Location: CRL 40.051 (second floor open-access NMR lab)

Spectrometer, probe and software specifications:  2-channel Bruker AVIII HD nanobay 400 MHz spectrometer running TopSpin 3, equipped with a 5 mm z-gradient multinuclear BBFO probe

 

Sample changer: 60-position Bruker SampleCase robotic sample changer

Access level: Open-access instrument operation

Experiments: Routine 1H and 13C based 1D and 2D experiments as well as additional multinuclear experiments supporting inorganic chemistry

History lists: Click here or copy and paste this link into a browser (note departmental login / VPN is required): file://chem.ox.ac.uk/SRF/NMR/Venus400/setup.html

Spectrometer details for publication requirements: NMR spectra were recorded on a Bruker AVIII HD Nanobay 400 MHz NMR spectrometer, equipped with a 5 mm z-gradient multinuclear BBFO probe using the software TopSpin (version 3, Bruker BioSpin)

AVF400: Bruker AVIIIHD 400 Nanobay

Image
avf400 web

Spectrometer nickname: AVF400 (not to be used in publications)

Location: CRL 30.049, (first floor, open-access NMR lab)

Spectrometer, probe and software specifications: Bruker 2-channel AVIII HD nanobay 400 MHz spectrometer running TopSpin 3, equipped with a 5 mm z-gradient multinuclear BBFO probe

Sample changer: 60-position Bruker Sample Xpress robotic sample changer

Access level: Open-access instrument operation

Experiments: Routine 1H and 13C based 1D and 2D experiments as well as 1D 19F and 31P experiments  (see the list of available experiments)

History lists: Click here or copy and paste this link into a browser (note departmental login / VPN is required): file://chem.ox.ac.uk/SRF/NMR/AVF400/setup.html

Spectrometer details for publication requirements: NMR spectra were recorded on a Bruker AVIII HD Nanobay 400 MHz NMR spectrometer, equipped with a 5 mm z-gradient multinuclear BBFO probe using the software TopSpin (version 3, Bruker BioSpin)

AVH400: Bruker AVIIIHD 400 Nanobay

Image
avh400 web

Spectrometer nickname: AVH400 (not to be used in publications)

Location: CRL 20.055 (ground floor open-access NMR lab)

Spectrometer, probe and software specifications: 400 MHz spectrometer, 2-channel Bruker AVIII400 HD Nanobay instrument running TopSpin 3, equipped with a 5 mm z-gradient multinuclear BBFO probe

Sample changer: 60-position Bruker Sample Xpress robotic sample changer

Access level: Open-access instrument operation

Experiments: Routine 1H and 13C based 1D and 2D experiments as well as 1D 19F and 31P experiments  (see the list of available experiments)

History lists: Click here or copy and paste this link into a browser (note departmental login / VPN is required): file://chem.ox.ac.uk/SRF/NMR/AVH400/setup.html

Spectrometer details for publication requirements: NMR spectra were recorded on a Bruker AVIII HD Nanobay 400 MHz NMR spectrometer, equipped with a 5 mm z-gradient multinuclear BBFO probe using the software TopSpin (version 3, Bruker BioSpin)

AVG400: Bruker AVIII HD 400 Nanobay

Image
avg400 web

Spectrometer nickname: AVG400 (not to be used in publications)

Location: CRL 20.055 (ground floor open-access NMR lab)

Spectrometer and software specifications: 2-channel Bruker AVIII HD Nanobay 400 MHz spectrometer running TopSpin 3, equipped with a 5 mm z-gradient multinuclear BBFO probe

Sample changer: 60-position Bruker SampleXpress robotic sample changer

Access level: Open-access instrument operation

Experiments: Routine 1H and 13C based 1D and 2D experiments as well as 1D 19F and 31P experiments  (see the list of available experiments)

History lists: Click here or copy and paste this link into a browser (note departmental login / VPN is required): file://chem.ox.ac.uk/SRF/NMR/AVG400/setup_2.html

Spectrometer details for publication requirements: NMR spectra were recorded on a Bruker AVIII HD Nanobay 400 MHz NMR spectrometer, equipped with a 5 mm z-gradient multinuclear BBFO probe using the software TopSpin (version 3, Bruker BioSpin). It was funded as an instrument upgrade by the EPSRC as part of the Centre for Doctoral Training (CDT) in Synthesis for Biology and Medicine.

AVB400: Bruker Avance NEO 400 Nanobay

Image
avb400

Spectrometer nickname: AVB400 (not to be used in publications)

Location: CRL 00.086 (basement NMR lab)

Spectrometer and software specifications: 2-channel Bruker Avance NEO Nanobay 400 MHz spectrometer running TopSpin 4 equipped with a 5 mm z-gradient broadband multinuclear SMART probe

Sample changer: 16-position SampleXpress Lite robotic sample changer (default) or a 60-position SampleXpress robotic sample changer.

Access level: It operates as a bookable instrument for 'hands on' trained users under automation and/or manual control.

Experiments: Routine 1H and 13C based 1D and 2D experiments as well as (but not limited to) 19F, 31P, 11B, 27Na, 29Si and diffusion-based experiments. 

History lists: Click here or copy and paste this link into a browser (note departmental login / VPN is required): file://chem.ox.ac.uk/SRF/NMR/AVB400/setup.html

Spectrometer details for publication requirements: NMR spectra were recorded on a Bruker Avance NEO Nanobay 400 MHz NMR spectrometer, equipped with a 5 mm z-gradient broadband multinuclear SMART probe using the software TopSpin (version 4, Bruker BioSpin).

 

HXY400: Bruker AVIII HD 400

Image
hxy400 web

Spectrometer nickname: HXY400 (not to be used in publications)

Location: CRL 00.086 (basement NMR lab)

Spectrometer and software specifications: 2-channel Bruker AVIII HD 400 MHz spectrometer running TopSpin 3. The equipped probe is dependent on the sample analysis requirements. 

Access level: NMR facility members only.

Experiments: The HXY400 is used for solid-state analysis with a wide range of experiments available. For more information, contact Nick Rees. 

Spectrometer details for publication requirements: NMR spectra were recorded on a Bruker AVIII 400 MHz NMR spectrometer using the software TopSpin (version 3, Bruker BioSpin).

 

HFX400: Bruker AVIII HD 400

Image
hfx400 web

Spectrometer Nickname: HFX500 (not to be used in publications)

Location: CRL 00.086 (basement NMR lab)

Spectrometer and software specifications: Bruker AVIII HD 400 MHz wide-bore spectrometer, 2-channel Bruker Avance III 400 instrument running TopSpin 3. The equipped probe is dependent on the sample analysis requirements. 

Access level: NMR facility members only.

Experiments: The HFX400 is used for solid-state, micro-imaging and diffusion analysis,with a wide range of experiments available. For more information, please contact Nick Rees. 

Spectrometer details for publication requirements: NMR spectra were recorded on a Bruker AVIII HD 400 MHz NMR spectrometer using the software TopSpin (version 3, Bruker BioSpin).

 

AVB500: Bruker AVIII HD 500

Image
avb500

Spectrometer Nickname: AVB500 (not to be used in publications)

Location: CRL 00.086 (basement NMR lab)

Spectrometer, probe and software specifications: Bruker AVIII HD 500 MHz spectrometer, 2-channel instrument running TopSpin 3, equipped with a 5 mm z-gradient broadband 1H/19F–X multinuclear (BBFO) SMART probe.

Variable temperature capabilities: BCU-I temperature regulation unit, with liquid nitrogen heat exchanger or evaporator for low-temperature work. Temperature range is approximately 193 - 373 K, depending on the set-up.

 

Sample changer: 16-position SampleExpress Lite robotic sample changer (not pictured)

Access level: It operates as a bookable instrument for 'hands on' trained users and NMR facility staff under automation and/or manual control.

Experiments: Routine 1H and 13C based 1D and 2D experiments as well as (but not limited to) 19F, 31P, 11B, 27Na, 29Si and diffusion-based experiments. 

History lists: Click here or copy and paste this link into a browser (note departmental login / VPN is required): file://chem.ox.ac.uk/SRF/NMR/AVB500/setup.html

Spectrometer details for publication requirements: NMR spectra were recorded on a Bruker AVIII HD 500 MHz NMR spectrometer, equipped with a 5 mm z-gradient broadband 1H/19F–X multinuclear (BBFO) SMART probe using the software TopSpin (version 3, Bruker BioSpin)

 

AVX500 : Bruker AVIIIHD 500

Image
avx 1

Spectrometer Nickname: AVX500 (not to be used in publications)

Location: CRL 00.086 (basement NMR lab)

Spectrometer, probe and software specifications: Bruker AVIII HD 500 MHz spectrometer running TopSpin 3 with a 5 mm triple-resonance TBO probe with multinuclear capability. This can provide H/F/X experiment combinations e.g. 13C with simultaneous 1H and 19F decoupling.

 

Variable temperature capabilities: BCU-II temperature regulation unit for work down to 233 K, with liquid nitrogen heat exchanger or evaporator for super low-temperature work. Temperature range is approximately 193 - 373 K, depending on the set-up.

Sample changer: 24-position Bruker SampleCase robotic sample changer

Access level: It operates as a bookable instrument for 'hands on' trained users and NMR facility staff under automation and/or manual control.

Experiments: Routine 1H and 13C based 1D and 2D experiments as well as (but not limited to) 19F, 31P, 11B, 27Na, 29Si, diffusion-based experiments as well as H/F/X combination experiments e.g. 13C with simultaneous 1H and 19F decoupling.

History lists: Click here or copy and paste this link into a browser (note departmental login / VPN is required): file://chem.ox.ac.uk/SRF/NMR/AVX500/setup.html

Spectrometer details for publication requirements: NMR spectra were recorded on a Bruker AVIII HD 500 MHz NMR spectrometer, equipped with a 5 mm triple-resonance TBO H/F/X probe using the software TopSpin (version 3, Bruker BioSpin). It was funded as an instrument upgrade by the EPSRC as part of the Centre for Doctoral Training (CDT) in Synthesis for Biology and Medicine.

AVD500: Bruker AVIII 500

Image
avd500

Spectrometer Nickname: AVD500 (not to be used in publications)

Location: CRL 00.086 (basement NMR lab)

Spectrometer, probe and software specifications: Bruker AVIII 500 MHz spectrometer, 2-channel instrument running TopSpin 3 equipped with a 5 mm z-gradient broadband X–19F/1H BBFO SMART probe

Variable temperature capabilities: Equipped with a liquid nitrogen heat exchanger for low-temperature work. Temperature range is approximately 193 - 373 K, depending on the set-up.

Sample changer: 24-position Bruker SampleCase robotic sample changer

Access level: It operates as a bookable instrument for 'hands on' inorganic trained users and NMR facility staff under automation and/or manual control.

Experiments: Routine 1H and 13C based 1D and 2D experiments as well as (but not limited to) additional multinuclear experiments and diffusion based experiments supporting inorganic chemistry.

History lists: Click here or copy and paste this link into a browser (note departmental login / VPN is required): file://chem.ox.ac.uk/SRF/NMR/avd500/setup.html

Spectrometer details for publication requirements: NMR spectra were recorded on a Bruker AVIII HD 500 MHz NMR spectrometer, equipped with a 5 mm z-gradient broadband X–19F/1H BBFO SMART probe using the software TopSpin (version 3, Bruker BioSpin)

AV600: Bruker AVIII HD 600

Image
av600

Spectrometer Nickname: AV600 (not to be used in publications)

Location: CRL 00.086 (basement NMR lab)

Spectrometer, probe and software specifications: 2-channel Bruker AVIII HD 600 MHz spectrometer running TopSpin 3, equipped with a dedicated 5 mm BB-F/1H Prodigy N2 cryoprobe optimised for multinuclear observation

Sample changer: 24-position Bruker SampleCase robotic sample changer

Access level: It operates as a bookable instrument for 'hands on' trained users who have undergone additional training, and NMR facility staff under automation and/or manual control.

Experiments: Routine 1H and 13C based 1D and 2D experiments as well as (but not limited to) 19F and 31P experiments. The cryoprobe has zero fluorine background so is well suited to studies of fluorinated ligands and proteins. The instrument is used for projects supporting biomedical research at the chemistry–biology interface.

History lists: Click here or copy and paste this link into a browser (note departmental login / VPN is required): file://chem.ox.ac.uk/SRF/NMR/AV600/setup.html

Spectrometer details for publication requirements: NMR spectra were recorded on a Bruker AVIII HD 600 MHz NMR spectrometer, equipped with a 5 mm BB-F/1H Prodigy N2 cryoprobe using the software TopSpin (version 3, Bruker BioSpin).

NEO600: Bruker Avance NEO 600

Image
neo600

Spectrometer Nickname: NEO600 (not to be used in publications)

Location: CRL 00.086 (basement NMR lab)

Spectrometer, probe and software specifications: 2-channel Bruker Avance NEO 600 MHz spectrometer running TopSpin 4 equipped with a dedicated 5 mm BB-F/1H helium-cooled cryoprobe optimised for multinuclear observation

 

Variable temperature capabilities: BCU-I temperature regulation unit for low-temperature work. Temperature range for analysis is 238 - 403 K.

Sample changer: 60-position Bruker SampleXpress robotic sample changer

Access level: NMR facility staff only. The NEO600 is solely used to run samples submitted via the NMR submission service.

Experiments: Routine 1H and 13C based 1D and 2D experiments as well as (but not limited to) 19F, 31P, 11B, 15N and  29Si experiments

Spectrometer details for publication requirements: NMR spectra were recorded on a Bruker Avance NEO 600 MHz NMR spectrometer, equipped with a 5 mm BB-F/1H helium-cooled cryoprobe using the software TopSpin (version 4, Bruker BioSpin). This spectrometer was funded by the John Fell Oxford University Press Research Fund and an EPSRC Strategic Equipment Grant (EP/T019190/1).

AV700: Bruker AVIII 700

Image
av700

Spectrometer Nickname: AV700 (not to be used in publications)

Location: CRL 00.086 (basement NMR lab)

Spectrometer, probe and software specifications: Bruker Avance III 700 MHz spectrometer, four channel instrument running TopSpin 3, equipped with a dedicated 5 mm 1H(13C/15N) inverse TCI cryoprobe optimised for 1H observation and with a cold 13C channel

 

Sample changer: a 483-position SampleJet robotic sample changer with sample chilling that is used for protein-ligand screening and metabolomics studies (not shown)

Access level: It operates as a bookable instrument for 'hands on' trained users who have undergone additional training, and NMR facility staff under automation and/or manual control

Experiments: Routine 1H and 13C based 1D and 2D experiments as well as more specialised experiments for these nuclei (WaterLOGSY for example), used in support of projects at the chemistry-biology interface. 

History lists: Click here or copy and paste this link into a browser (note departmental login / VPN is required): file://chem.ox.ac.uk/SRF/NMR/av700/setup.html

Spectrometer details for publication requirements: NMR spectra were recorded on a Bruker AVIII 700 MHz NMR spectrometer, equipped with a 5 mm 1H(13C/15N) inverse TCI cryoprobe using the software TopSpin (version 3, Bruker BioSpin)